Answer Posted / abhishek singh
Core balance CT (CBCT): The CBCT, also known as a zero
sequence CT, is used for earth leakage and earth fault
protection. The concept is similar to the RVT. In the CBCT,
the three core cable or three single cores of a three phase
system pass through the inner diameter of the CT. When the
system is fault free, no current flows in the secondary of
the CBCT. When there is an earth fault, the residual current
(zero phase sequence current) of the system flows through
the secondary of the CBCT and this operates the relay. In
order to design the CBCT, the inner diameter of the CT, the
relay type, the relay setting and the primary operating
current need to be furnished.
| Is This Answer Correct ? | 16 Yes | 3 No |
Post New Answer View All Answers
How cable from Kit-Kat to main switch, from starter to motor are designed?
WHY THE RATINGS OF THE TRANSFORMER IS 33KV WHY NOT OTHER???
Why we use mho Relay in long transmission line?
Bimetal strip used in overload relay what is that,which types of material used for that & percentage.
What are the causes of having an rmu explode after installation? And how do u treat the bushings of an rmu?
Explain Need of a starter in a dc motor.? Also explain any two starting and speed control method of dc motor?
(1)The demand for electricity , the amount of renewable generation available, the amount of fossil fuel generation available and the cost of the fossil fuel generation are shown in table below period(hrs) demand(MW) renewable (MW) fossil- fuel(MW) cost of fossil fuel(MW) 00.00 - 01.00 2000 1800 2000 30 01.00 - 02.00 2300 2500 2000 30 02.00 - 03.00 2500 2700 2100 45 03.00 - 04.00 2900 3100 2100 50 04.00 - 05.00 2700 2600 2500 45 05.00 - 06.00 2400 2000 2700 50 06.00 - 07.00 2200 1800 2000 36 07.00 - 08.00 2100 1600 2000 36 Assuming that the renewable generation incurs zero cost, determine an optimal generation schedule(specifying the amount of renewable generation and fossil fuel generation used in each period, the cost for each period and the overall cost for 8 hours.)
what topics we have to concentrate for power grid et.written test.and tell what to read for english synonyms and antonyms.
how to CHECK CT AND PT AT THE FAULT OCCUR IN GENERATOR RELAY PANEL .
diameter of cable and core is doubled then the value of capacitance is
Why are the laminations insulated from each other?
HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.
Compare salient pole and cylindrical rotor machines.
Explain in details how you would react to an unexpected incident when your supervisor or manager is not around to give instructions?
What is an iron loss or core loss pi?