what is the Knee point Voltage?

Answer Posted / rajeshpandian

Apply the voltage to secondary in ct,which point magnetising
current increases 50 % rise of voltage 10%.taht is called
knee point voltage.If you increase the voltage after the
Knee point u get the abnormal magetising current.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between Generator Differential Relay and Transformer Differential Relay?

1713


Cables Construction hi friends, 0.6/1/1.2 kV LV , DC and Control cables are concentric copper conductor what does its means and what is the use of concentric copper conductor,and are this with copper tape shield or copper screening, ? thanks

1301


i am completed in B.E(Electrical and Electronics Engineering) with 8 months experience in Quality Control Engineer at Bharathi Industries,Coimbatore.

1474


what is the most permissible winding temp when we conducting a generator load test?(condition no load)

1227


How can we measure earthing resistance test (Earth meggar) of Transformer neutral pit while in live condition?.

1631






I am apply the AAI. So i want electrical sample question paper in technical with answer my id is vijayjobsmart@gmail.com

2206


some time we open engine breaker 8.0 MW load but plant not trip. and another time engine open 4.0 MW load engine trip why? individually engine breaker open & individually emergency stop why difference?

1309


What is the reason behind current flow(20 A) in amain earth cable of an SMDB? Is cuurent flow(45A etc) through a neutral cable acceptable?

1505


how to extend relay operating timing in 24V dc relay card (without using Timer )

1465


what is the difference between directional & non directional earth fault with example please explain.

1347


How will polarity test of Dy5 Transformer ?

1699


if the number of poles generated in stator and rotor side of an induction motor are different then what will happen and why?

1358


State any two nuclear power stations in India, with their generating capacity.

1391


we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan

1222


why any centrifugal blower draw more current in starting. consider id fan and fd fan?

1367