To prevent the mal operation of a differentially connected
relay while energizing a transformer, the relay restraining
coil is baised with
(a)second harmonic current
(b)fifth harmonic current
(c)third harmonic current
(d)seventh harmonic current
Answer Posted / enggrashmi
2nd harmonic
| Is This Answer Correct ? | 16 Yes | 2 No |
Post New Answer View All Answers
An active element is one which a. Supplies energy b. Absorbs energy c. Supplies energy and convert energy from one form to another
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
what is the function of Moulded case circuit breaker, why it is called Moulded?
ht side line to earth voltage
Can any body tell me about INNER SHUNT COMPOUND MOTOR diagram?
how to test YNyn0 vector group in transformer?
How o select the electrical fuse?.What are its characteristics.How to select the material od fuse?
A cable with concentric PE conductor must be used with frequency converter circuits what does its means.?
Explain about technical and non technical losses in distribution system?
How to reduce the static electricity producing in solvent room? By P.D.Patil BioCon
Will any motor burn if voltage provided is lesser than the rated voltage???? If yes, then how is speed control possible with voltage control
is that a problem if i connect a single phase load to a secondry delta connected transformer but i get a neutral from other transformer i the system?
what is the solution for meger test failed the MV cable?
I have c license but I don't know eligibility of Max Kilo Volts under the electrical licensing board.
What are the necessary components of the feedback control system?