Why DC current is not used in transformer?

Answer Posted / chiranjit ghosh, hetc

WE KNOW XL=2(pi)FL.IN CASE OF DC F=0. AS F=0, XL=0 ALSO. SO
THERE IS NO INDUCTIVE REACTANCE IN THE PRIMARY CIRCUIT IF DC
IS FED TO TRANSFORMER.THE PRIMARY WINDING BEHAVE LIKE SIMPLE
CONDUCTOR.NOW ITS LOOK LIKE U GIVE A DC VOLTAGE ACROSS A
CONDUCTOR. THE PRIMARY WINDING(CONDUCTOR) WILL HEATED UP AND
WINDING BURN DUE TO HEATING.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

circuit diagram of trip circuit supervision relay

1593


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

975


How to calculate flow of water delivered by pump when pressure & size of pipe line is given

1782


'documenˁ

1519


explain me the relation between torque, frequency,speed,voltage and current in the 3 phase induction motor?

1754






please send me jindal previous aptitude and technical question and answer.my email id is deep_raj@live.com

1497


Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?

1039


Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.

1841


what is the current density of copper & alluminium.

1504


How i can calculate current of cable according to ares?

1418


what is the max. acceptable leakage current in 33kv bus bar

2508


What is the unit of charge and current?

629


can someone explain that how the speed of the protection system affects the fault level calculation?

1472


i have applied for the post of RRB section engineering chennai board please send me previou papers and solved answer. my mail id jagarapusrinivas@gmail.com

1482


how calculated Transformer losses.

1572