Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

is there any chance to get shock from the transformer oil at
the time of maintenance due to its dielectric property. . ?

Answer Posted / hareesh

Oil is having a insulating property so by touching the oil how can u getting shock? there is no shock by touching oil

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Dear all, how we select the cable size according  to current with or without including different correction factor , is there any direct method for sizing of cable... 

2162


dg started in plc mode and load taken later one battery terminal connection will be disconnected by loose connection what will happen for dg and shall we connect battery terminals while dg in load time?

2074


Merits & Demarits of Oil circuit & Air circuit breakers ?

2080


What do you mean by the zone of protection?

1097


types of central Air conditioner plant?

2172


whatis the commertial spec. of distribution boards ?

2075


What is meant by vector group

2541


how to enter inverter parameter? without manaual?

2037


what is thresold of perception

2076


Can 33kva/415v transformer be run underground? If the answer is yes why and if the answer is no why?

1582


Is RTCC panel needs any control supply.

2052


How to do cable earhing? whether by grounding Armour to ground or by running extra G.I wire along with cable? which one is preferred mostly amoung them? If the second one is more preferable how many GI wires to be run along with cable (1 or 2)?

2140


A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?

5281


how to test the electrical panel.ht lt mcc pcc.

3780


IN SINGLE PH TRANSFORMER IF LEKAGE IMPEDANCE DROP IS NEGLECTED ,THE FLUX IN THE MAGNETIC CORE and the lekage flux linking a winding are a)proportional to the applied v to the winding i respectively.

2119