motor work in hat principle
generator work in what principle
transformer work in what principle
pls explain with details or answered to
ramadoss.sepc@gmail.com
Answer Posted / rajesh
THE ONLY THING COMMON TO ALL 3 OF THE MACHINE IS TRANSFORMER ACTION . CONSTRUCTION WISE ALL ARE DIFFERENT .
ALL REQUIRE MUTUAL COUPLING BETWEEN EITHER
PRIMARY /SECONDARY COILS
STATOR/ROTOR COILS
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
could an induction motor be used for regenerative braking in electric-train control? in this type of application would some scheme have to be devised to obtain low synchronous speeds while braking? would induction-motor drive, therefore, be suitable for passenger service?
What is meant by Load Encroachment in OHL Feeder Protection?
what is ramping rate of generator
What do you mean by ratio correction factor of instrument transformer?
State uses of different types of stsrters with different capacities of motors as below: a. up to 5HP b. above 5hp to 10hp c. above 10hp to 20hp d. above 20hp
What is conventional thermal current (Ith)
what is the function of anti pumping relays? what is KVAR? How it is generated in alternator? What is 3rd Harmonics? What is IDMT relay?
Sir, I have applied for the of Jr.engineer(Electrical & Electronics) & ASST. LOCO PILOT at ALL RRB BOARDS. please send me all RRB Boards solved papers in the year of 2001 tO till date. i requested send me the papers to my id as soon as possible (jet_0991@yahoo.com). (This is very urgent) Thank You,
Role of active and reactive Power sharing in between two synchronized Generators, Droop Setting role ?
How many turns are there in primary winding? (In Transformer)
What type of wiring series or parallel is used for conventional and addressable type FAS & why?
1)how to reduce the value of tan delta of trasformer and CB,bushing,CT&PT,CVT ? 2)how to reduce the resistance of CB contact and its operating time? 3)plz.....send me the project report on conditioning and monitoring of substation equipment on my email id (gusaiyogendra03@gmail.com)
If I bring a basic electric meter from the States and hook it up in Costa Rica in a development that has only one transformer for the 50 homes, will it still be accurate regarding the usage of kilowatt hours?
Damping resistor provided in open delta (tartiary) winding of a measuring PT at the incoming of a MV inverter drive panel is getting heated up. Can any body explain the reasons and suggest the remedy?
how to identify vector group of three phase transformer by voltage method?