What is loop checking ?
Answer Posted / scheau vlad
Loop check activity is checking entire loop functionality, from field to DCS or Esd or plc or any logical system. It is necesary to check not only continuity of signal, but also range of calibration, alarms, set points and any signal included in the loop folder. For DCS will be tested with hart comunicator or temperature generator, 4-20mA, depends of witch instrument is involved. For Esd (emergency shut down system) loop check will be done with proper instrumentation tools to produce the specific presure or requaired level... For valves you must check all signals as open, close, hi and low limit switch, reset buttons, hand switches , feedback must be check and a lot of other things must be checked .. Loops are direct, revers, split range .. it is not easy and it is not only the continuity check to do.
Is This Answer Correct ? | 84 Yes | 7 No |
Post New Answer View All Answers
why use 50% lel methane gas concentration for gas detector calibration instead of 60% lel gas concentration whereas the hi alarm set at 60% lel.
Name different types of bourdon tubes.
Explain the difference between mmwc and mmwg?
State four different types of flow measurement, for gas flow measurement MMSCFD is the common unit expand the unit and specify significance of word S in the unit.
all types of liquid analyzer principle with drawing?
what are the diff. in servo and regulatory control?
What is feed factor and its Importance in cement industry? How we can solve feed factor?.
Somebody can explain me about >Critical Loops, calibrations, ESD critical Loop checks, Logic Diagram / Cause & Effect checks for ESD loops,
Gas equation
any one can send me instrumentation previous interview papers? I prepare for MNC Company Interviews? my mail id- Rakesh.Golla@dodsaldxb.ae , and another mail rakesh.gvk@gmail.com
pls suggest suitable MOC of diaphragm for pressure measurement of UREA grade solution service fluid.
Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.
For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?
is motorized valve closed when power shutoff?
Why 4-20 amps is being used in instruments? Why cant we use any other range instead of 4-20 amps? Why only 4 amps is taken as lower limit and why 20 amps is taken as the higher limit?