Answer Posted / jyoti-theboss
Induction motor works on the Faraday's law of mutual or
electro magnetic induction.Which states that if" Two coils
are inductively coupled(not electrically connected,but
closely connected without touching each other so that,flux
linkage can occur),if current flows in one circuit there is
production of emf in the neighbouring circuit.
so if power supply is given to the stator winding a
magnetic flux of constant magnitude but rotating at
synchronous speed is set up.it sweeps past the rotor
surface & cut the rotor conductors and emf induced in
them.As per Lenz's law"It opposes the very cause producing
it".So to reduce the relative speed (between rotating flux
and stationary rotor conductors) rotor starts running in
the same direction as that of the flux.
| Is This Answer Correct ? | 7 Yes | 0 No |
Post New Answer View All Answers
What is Scheme Test of High Voltage Switchgear. Which tests it includes.
Why current shoots up in the secondary on the knee point voltage during saturation test of CT? How core saturation effects the secondary current (while the primary side is open)? What the logic behind this?
what is metering cum synchronizing panel and how it is used?
What is the different between conventional MCC and intelligent MCC? Common controller or controller for each bucket
what is difference between bus coupler and auto transfer switch
Define peak overshoot.
concept of busbar and load dispatching..?
why Y CONNECTION IS BETTER INTERMS OF EFFICIENCY AND P.F FOR A LAOD LESS THAN 40% AND WHY AFTER DELTA IS BETTER FOR > 40%
75 kw motor take 45 amp in no load delta in star 10 amp but in load it will take 160 amp but IR velue of winding above 500 at 1kw ph to earth and ph to ph. what problem it should be?
SUTIABLE FOR ohm's law super conductor
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
What is I to C?
sir, what is the importance of Fault MVA. how to calculate fault mva of 33kv substation connected by 6.5 km line(single circuit with equal spacing) with 110/11kv transformer in 110kv susbstation.the fault mva on 11 kv bus in 110kv susbstation is 208mva.
What are n circles?
Dear Sir I am living in Jaipur Rajasthan now I did complete my b tech degree in electrical engineering in 2012 Sir how I gate certificate of competency for electrical supervisor