Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

difference between DCS @ SCADA system?
and how can use in field

Answer Posted / jigneshsolanki

THERE IS MAINLY TWO DIFFERENT BEETWIN dcs & scada SYSTEM
1) DCS system it self whole control system & SCADA system required plc for controlling.

2)dcs SYSTEM scan time is nearly 1sec & SCADA with PLC system scan time is in millisecond(depends on program).

3)DCS having Large I/O capacity with respect to SCADA with PLC system.

Is This Answer Correct ?    5 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

plz send me general of ongc

1944


few questions on RS 232,1 question on relationship of impedance and turns ratio, many questions on flowmeters

2020


What is instrumentation measurement?

1098


I have a Control VAlve having size of 2 ".Only the known parameter is Pressure drop . Its 2 Kg. Then How to calculate control valve sizing means Cv.

2337


What is profibus?

1109


Positioner usage.

1909


How to calibrate displacer type level transmitter (chemtrol make )for level measurement in hotwell , LP & HP heater ?

5890


send me last 5 years questions asked in rrb chennai, for section engineer

2084


What happen if we install my pressure transmitter below the elevation of pipe in natural gas service?

1044


in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.

2792


any body who gone thru recent iocl interview.INSTRUMENTATION questions. I need.

2471


how to connect transmitter measuring sulfur process? 1-by using long impulse line or 2- by using coated short impulse line

2093


Programmable Logic control.

1940


while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?

1879


components of control circuit belongs to control valve

1641