Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why do we use star-delta starter. what is its need?

Answer Posted / sduhakar

We use star to delta bcoz it can reduce the motor current carrying capacity up to 1/3 times. For DOL stater it's starting current and running is same

Is This Answer Correct ?    19 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

2- What are the percentages between excitation currents in phase (R, S and T) in ∆ and Ỵ connections in excitation Current test in transformers?

2067


what is the relation between reactive power and power factor for the what is the limit of reactive power and power factor

2149


What is the test block protection relay if any body know plz explained

1521


what is the relation between size of the anteena and wavelenghth of radiated wave

2238


Define sensitivity?

1146


what are the breakdown voltage rating of mini- curcuit'transfarmer!

2216


where the lexical paramater will use in fron end?

1924


Generation of voltage for each phase are same of a turbogenerator.Although the short circuit current flow when two phase of turbogenerator are shorted(where current can't flow without potential difference),why?

2167


A power transformer 4MVA/11KV/0.415Kv has been out of use in 12years. what maintenance actions/test need to be carried out before energizing.

1368


As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?

1812


what is the difference between single ratio, multiple core and multiple ratio, multiple core ? please explain.

2239


Why we find the sensitivity for the CT's to check?

1914


Which type of motor is used in trains, what is the rating of supply used explain working principal?

1332


i have interview in Pepsi company what type of question will ask please send the question and answeer

3518


i want to run 11kv star connected motor in 6.6kv with delta connected throught inverter, is it possible?

2084