Which one is correct mVA or MVA. Whether both the units are
same for the transformer
Answer Posted / pinku
MV.A (not 'MVA') is the symbol for megavolt ampere.and in some low volatge cases we consider VA that is (Voltage Ampere). where VA is the true vector sum of circuit power or reactive power.
So, i thik it is true. NOT 'mVA' in case of transformer.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
WHAT IS DOL STARTER? HOW IT WORK? GIVE ITS CONTROL AND POWER DIAGRAM .
how can i determine the KVA/MVA rating of transformer precisely?? is there any standard test?????
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
The power factor of the fixed load is 0.8, now the p.f is varying from 0.8 to 0.5.
how do you choose the cable size as per amps rating & the voltage drop for the same.
what is the ATS .And how it works.
difference between high and low impedance BUS BAR relay??
HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.
take 100kva DTR( delta/wye ), what ll happen if we connect 11kv to LT side instead of connecting to HT side? will the DTR behave as a step up transformer or something else????
WHY THE RATINGS OF THE TRANSFORMER IS 33KV WHY NOT OTHER???
What are the three major categories of error?
Can you used moeller lzm1 mccb in a dc system with 125vdc and 20ka short circuit current , beside is it have 24 or 48 volt shunt ? Beside how long current can through from An MCB shunt contacts? (like Z7-AS 24 V)?
cc of scorpio?
What is genrally the % Impedance of a Dg set? How can we calculate Earthing conductor size for a DG set?
How do the synchronizing lamps indicate the correctness of phase sequence between existing and incoming alternators?