why electric shock due to dc is dangerous than that of ac
Answer Posted / alok singh
MY Bro Pradeep kumar who tells you that Dc is not harmfull , The railway traction system supply is completely dc transmission, even though all the high tension transmission is done using dc supply, the actual reason is that in ac once when its cycle comes to zero u get a chance to be left from shock but in d.c once u get shock u wont as it has only positive cycle.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
State angle criterion.
what should be correct gas pressures to be a 1.5 ac unite
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.
how wecalculate breaking capcity of acb mcb mccb .explain with example
Why delta star trformers are used for lighting loads?
what happens when series resonance occurs?
calculate external resistance values to add to the rotor of a slip ring induction motor. STATOR- 415 V, 3 phase delta, 1100 A, 50 Hz, 1490 rpm, pf 0,86 ROTOR - 660 V, 590 A, 50 Hz. STATOR current at each steps STEP1-600A,STEP2- 800A,STEP3-1000A,STEP4-1100A.
why constant voltage transformer should be start without load? and if started then what will happen?
What is the difference between amorphous core transformer and CRGO core transformer?.
what is the affect of earth's magnetic field on the frequency used in aircraft???
How the annunciator works ? How to do its wiring
what is the control circuit for operating the clean room air shower
What is the normal phase difference between the voltage and the no-load current in a transformer?
300m long and 30kw inductive loade 3phase supply how many size cable required