If two transformers same rating(11KV / 440V)connected in the
same primary line(11KV), can we connect(bus coupler)
secondary side directly or need a synchronization????
Answer Posted / muthuvel
No,If you connect Bus coupler between the secondary sides of
transformer.. Trans will get parallel operation.This will not
be possible we cannot able to make parallel
operation,synchronise the transformer to make that all the
elec characteristics should be equal for the transformers.
| Is This Answer Correct ? | 4 Yes | 4 No |
Post New Answer View All Answers
Hi everyone, I'm Lachuu, recently joined automation company as PLC Engineer. I have certain basic question, I request all big gurus and seniors to answer these question. Because this will be very helpful to me as well starters like me. How to design a control circuit (ex: pick & place - my current project) Yamaha robot PxYx series controller RCX222, using 6 cylinder double acting, plc keyence kv p16r 2 expansion unit for input and output each. How to select panel terminal mcb elcb powersupply. My main concern in some projects how to select dc power supply, mcb rcb(I came across dif bt b c d curves, but stil confusing, pls help me :-(. I would really appreciate all who are going respond to this question.
If the Brush of DC motor is shifted by 90 deg, then what happens to voltage and torque? Both voltage and torque are zero. how to justify the answer?
How do we calculate over and under frequency tolerance from generator data?
What are conduct on the testing in cf in ur site?
what kind of technical test that i need to learn because i have an interview tomorrow.. please someone help me..
in control scheme dc logic wiring commonly using negative loop,what is the reason?if we use positive looping what will happen?
State the other types of Air Conditioners?
What is Load sharing of Transformer ?
when the time of backcharging the transformer three phases only enough or three phase with neutral is must.from these which one is the best one.
hai...... tis is Hemanth. jst now completed electrical engineering... i wanna to apper for ap tranco exam... plzz send me the previous q's paper link......thanx in advance.
While testing LA mast,What are the parameter limits ?
Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.
i m in need of current rating chart of heavy duty pvc/xlpe, cu/al cables. can somebody provide me? if yes, plz send me at ashish_patel111@yahoo.com
what are the main applications of transistor in non-linear region?
In Designing the rating & accessories of a MCCB how to choose the type of releases..means what is the basis for selecting, thermal magnetic, electromagnetic & microprocessr based releases