why is corona loss greater in a stranded conductor as
compared to a solid conductor ?
Answer Posted / sunny
In solid conductor the inductance is more as compare to solid conductor. To reduce the affect of corona hollow and bundled conductors are used.
| Is This Answer Correct ? | 3 Yes | 4 No |
Post New Answer View All Answers
What the main causes of transient interruptions on Over-Head Distribution Lines?
What is the reason of polyphase induction motor tripping suddenly on high current during running at 70% laod? Motor IR , winding resistance & inductance balance. Motor no load current is balance and ok as per mgfr. data.
we have provided 30 nos. relay contacts in panel.I want to know how do we do the numbering for the relay contacts as per any applicable standards
which book to refer in electrical engineering for iocl exam & which book for general english.
State thevenintheorem?
EXPLAIN WHY THE SURGE CURRENT RATING OF AN MCCB OR CIRCUIT BREAKER DECREASES WITH INCREASE IN THE RATING OF MCCB OR CIRCUIT BREAKER.
what is the voltages using in movie theaters??? why ??why not other??
I want to put this query to SENIOR & EXPERIENCED ELECTRICAL ENGINEERS. 1)I want to know about the control circuit diagrams for control panels. I found it difficult to understand. Is there ant booklet through which we can learn the circuit diagrams? 2)I want to learn about conduiting, laying cables, preparing cable schedules and various techniques which is the part of building infrastucture(construction field). I don't have any experience in this area. I have experience in control panels only. that's why i am not getting any opening in building infrastucture (construction field).Can I get the job in this field as Trainee Engineer? How to enter this field? I need job in PUNE
How to measure the earth resistance value in a concrete pavement(flood light area)?
Define what is difference between fuse and breaker?
Discribe type of fault in DOL and stardelta startor.
What do you understand by oldham's coupling ?
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain
What is the basic of DTH.
how i calculate the syncrones generator NGR resistance .if we have a 6mw generator line voltage of generator 11kv also line current 393.3 ampere.