Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why C.T secondary are rated 5A generally?

Answer Posted / eng . ammar al-qudah

it depends on the purpose of the CT , when we install the CT before a protection device , a 5A CT will be installed for the most protection device , and when the CT are needed for measurement system the choice will be 1A for more accuracy , so we can't give a certain answer for this , it depends where we use it .

Is This Answer Correct ?    2 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I HAVE BEEN SELECTED FOR APGENCO A.E(ELECTRICAL) 2008.HOW MUCH WEIGHTAGE FOR INTERVIEW AND WRITTEN TEST.HOW I HAVE TO PREPARE. PLEASE GIVE INFORMATION IF U KNOW.WHAT ABT G.D THIS TIME.CALL RATIO 1:2

2864


plz send me Bhel, Mahagenco, sbi previous exam paper for electrical engineer on my email-id kambali_smita@yahoo.co.in

2365


The power factor of the fixed load is 0.8, now the p.f is varying from 0.8 to 0.5.

1928


Write the force balance equation of ideal spring element.

1204


What is dynamo function in DG sets and draw block diagram?

1979


why we use sinosidal voltage / current instead of others in system?

2145


1. Can a 12v DC choke operate a 60v/12w PL lamp ? 2. Can a 230v ballast fire / operate a 60v/12w PL lamps.

2140


What is the effect on in Zone and out zone fault if Phase side CT is Vk/2<30 mA and Neutral side is CT is Vk/4<30 mA for Transformer REF protection

3754


What happens if the series current double?

1421


what will happens if one phase is missing for 33/11kv power transfomer and why?

2592


What is the most important precaution in any experiment with d.c. Shunt motor?

1203


A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram

2767


What is the restart inhabit setting in ABB spam150c relay (Motor protection relay)

3584


In power transmission using open belts or horizontal shafts it is preferable to have the slack side of the belt on the top because

1162


how to caculate cable size for diff types of loads? if anyone know the calculating procedure please tell me

1379