Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Give me clear explanation.What is the Different Between Load break switch and Vacuum circuit breaker

Answer Posted / vinayak

the basic difference between the load break and vacuum
circuit breaker is the arc quenching media or mechanism.
In load break switch the arc is quenched by lengthening
using arcing horns, whereas in vacuum circuit breaker arc is
quenched by the removal of the metals vapors from the media
which are created by the separation of the contact.

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why 15Amp. MCB is suitable to carry load of 1.5Ton Ac please Explain?

2222


what questions are asked in the interview for the post of an electrical maintenance engineer in FMCG companies?

2759


Draw a SLD of HT distribution EB grid up to users Transformer?

6249


what is Fan Control Cubicle

2531


what is mppt (maximum power point tracking ) and how they used in solar power generation ??? what are the main components used in mppt?????

3378


What size cable (based on voltage drop) is required to supply a 40 A three phase boiler if the wiring system is 75V single insulated cables installed in non-metallic rigid conduit 56m from the main switchboard? Voltage drop in the consumer's mains is 8V.

2031


I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.

2158


What is hipot test procedure?

1521


comparision between ACB and VCB

2420


difference between high and low impedance BUS BAR relay??

1667


what is the effect of higher value of GD???

1861


When we have earthing mesh or underground earthing network in industrial plants, weather we have NT-S or NT-C-S kind of earthing system, so eventually weather we must use 4 or 5 wire in 400 volt level (For example 3×150+70 mm2 or 5×150 mm2) in this connection I would like to know exactly the paragraph of IEC or IEEE number

2228


A motor running with lenze frequiency inverter stops if I REDUCE SPEED with 25% load.If I run it in High speed and medium speed running smoothly with full load.please help me to solve it.

2043


how to calculate the loss tangent of electrical cables

2134


how to interlock 3 nos MCCBs using under voltage coil. please provide me circuit diagram?

2653