IAM WORKING IN THERMAL POWER PLANT AS A TRAINEE.. I WANT TO
IMPROVE MY CARRIER.,
IF ANYBODY KNOWS ANY COURSES., ANY TESTS, ANY BOOKS ,,
ANYTHING PLS HELP ME..
Answer Posted / chezhian
NPTI national power training istiuite for power plant training
in neyveli delhi nagpur and bangolur
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
I am apply the AAI. So i want electrical sample question paper in technical with answer my id is vijayjobsmart@gmail.com
With a phasor diagram show the effect of increasing the field current of a generator supplying a constant real power and connected to a grid system.
Instrument connected to a single phase supply
Why should be the frequency 50 hz 60hz only why not others like 45, 95 56 or anything , why should we maintain the frequency constant if so why it is only 50 hz 60hz?
We have studied about many techniques for finding the stability of system, ROOT LOCUS, ROUTH, BODE PLOT, POLER PLOT etc. In these which is used where. what are the difference among them... PLZ tell me.......
What happen Grid EARTH plat got cut.
please give me all the Alarm .Trip ,Safety Relays & Conditions of UPS Systems mail me on ashokbabunhce@gmail.com
some time we open engine breaker 8.0 MW load but plant not trip. and another time engine open 4.0 MW load engine trip why? individually engine breaker open & individually emergency stop why difference?
he compression ratio for a petrol engine generally lies between
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
how to calculate the capacitor to maintain power factor?
Define closed loop control system.
why we need to us lenz's law for synchornous motor
I Have 3 Phase 10 KW AC Alternator i found one phase weak, so what will be the reason & what action shouls i take to rectify the same.
Write the force balance equation of ideal dashpot element.