Answer Posted / muthuvel
In Transmission of Electrical Power,There is no need of Single Phase Output.The neutral is required where ever the Single Phase output is required.And If it is Star system means
we are required to give Three phase Four wire It is economically not good.So only Power System Always having Delta System in Transmission and Star System in Distribution This is very small basics of Transmission and Distribution System.
| Is This Answer Correct ? | 15 Yes | 2 No |
Post New Answer View All Answers
Which is the oldest hydropower plant in india?
when qty of cable being purchased is not sufficient according to the standard,what should the inspector do to ensure its quality according to the standard?
What are the basic properties of signal flow graph?
DC transmission
How to checked frequency drive output voltages?
Refernce currents are to be generated using refernce cueernts how can this be done
Show Details FROM:Muhammed Ikram TO:qa@allinterview.com Message flagged Saturday, June 4, 2011 10:07 PMMessage bodyHello all, i want to ask a question to all of you that what is VMM (voltage monitoring module )? how it work,s? i heard somewhere that it compare 1 phase voltage to other phase voltage. but there is also some setting on it. how to set it,s setting. please tell me briefly. Thank,s and Regard,s. Muhammed Ikram.
What is meant by turbo alternators?
two way ckt diagram can be drawn by how many ways? give diagram
How do you calculate the actual power consumption of an inductive load appliance. Say, a deep freezer of 200watts
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
do we use neutral grounding for resistive balanced load? if we use what happen?
How could I get a certificate of competency as Electrical Supervisor? I have completed By BTech in Electrical this year(2012) for VJTI Mumbai Maharashtra. Is it compulsory to be produced while joining?
How a band pass filter is constructed?
why HT armoured cable does not glanding