what is the use of megger? and types

Answer Posted / y.rajasekhar reddy

all mggers are insulation resistance testers offer the
electrician, maintenance engineer, and repair technician
flexibility, versatility, and capability of equipment.
there also used the all type of insulation test for cables.

Is This Answer Correct ?    10 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the functions of temperature scanner in power transformer?

1385


What is superposition theorem?

405


ratings of lightning arrester

1360


why on axial hitting up of air blast on hydrogen produced in oil circuit breaker,temperature rises of the core of the arc?

1155


what is the meaning of osr in transformer.

1261






How much dc volt applied in cathodic protection system?

1518


r we are using in gas turbine mark (5) frame (6) (made in india Bhel 1997) Ā

1071


transformer spections :: input voltage 0-110-230v; output volage 0-10-12-14v; amp=3A using CRNO CORE, capcaity=50VA primary turns = ? ; secondry turns =?

1312


For a 6.6kV Motor it is recommended to do megger test with 500 V d.c and not more than 5kV d.c but the Hi voltage withstand test should be performed by 12kV AC. Why the dc voltage test should be limited but AC voltage withstand test could be with such a high voltage?

1314


what is the basic need of domestic loads 1- voltage 2- current

1245


ELECTRICAL DRIVES: can a motor load system with passive load torque can have equilibrium speed in second quadrant

4456


what happen if drive input fail momentry at 48.5 HZ frequency?

1278


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1354


difference between servo motor and synchronous motor

1659


What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.

1548