Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why 5kv megger used to megger 6.6kv motor or 33kv
transformer why not 500v?

Answer Posted / sanjeet kumar singh

Megger is used to check whether the insulation is ready for
bearing the nominal voltage at which the equipment is to
run. Since, a 6.6KV motor is to face the voltage of 6.6KV;
hence it is to be tested with 5KV megger. On the other hand,
if you measure the megger of 33KV transformer with 500V
megger, it means that you are giving the pressure of 500V
only to a system which is claiming to be sustain 33000V of
pressure. Hence, the test becomes meaningless, because you
are giving only 500V to a system which has to bear atleast
33000V. In addition, we should also know that basic meeger
voltage are: 500V, 2500V, 5000V. Above that you have to go
Hi-POT test.

Is This Answer Correct ?    7 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Hi, My plant daily consumption is calculated as 3.8MWH but my supplier has sanctioned an power of 2.6MW per day. how can i equal or distinguish this two factors

1886


1.why we are using blocks in withoutgaplightning arrester 2.why we ar using bushing in withoutgap lightning arrestor

2013


kindly send me 11KV MV motor differential protection procedure by primary injection method.

1414


what is the difference between "Rotary bypass isolation switch and Normal bypass switch" pls share indepth techs?

2035


in the case of 6.6kv motor starter combination contain fuses on it VCB. but in 11KV motor starter combination Fuses are not using in it's VCB why?

2255


what is the working principle of energy saver control panel. please give the complete calculation & theory.

2422


how to find ratio of CT & PT in 66/11kv 12 mva supply system ? explain with calculation.

2385


what is invertor supply and raw powersupply

2088


If 22 KV HT line, Current transformer is 25/5 then how to calculate multiplying factor.

1075


What happened when capacitor connect series in ac circuit?

1464


What are the effects of adding a zero to a system?

1264


how external lighting design? please give examples?

1859


Why front mounted CT polarities are always towards breaker?

2012


what is the range of maximum DOL and SDS can be use for pump and fan application

1097


How to calculate the input cable rating for 10kva ups (3phase input and single phase output and also 3phase output, battery rating 65Ah)provide the formula also.thnx

2194