Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What are the effects of armature reaction on a DC machine
and discuss the various methods to reduce the effect.

Answer Posted / lakshmi

the effects of armature reaction are (i) de-magnetising
effect ( which means weakens the main flux) and (ii)cross
magnetising effect (which provides distortion to the main
magnetic field).
to reduce the effect of de-magnetising we provide extra
ampere turns to the armature which is given by the value
ATd = @m*ZI/360
and to reduce the cross magnetising effect we use inter
poles and compensating winding

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to calculate the conductor size for certain KV transmission line and distribution line?

2457


AL=0B9H,bl=75H, ADD AL,BL AL=____________? CF________? OF___________?

2613


Is any generator is developed which is operated with out diesal or other expensive source?

2062


On a 6 KVA UPS we have to provide a DC MCB for Battery bank of 16 nos (12 V 42 AH). What Shall be the current rating of DC MCB ?

2573


In CTs tan delta point should be earthed , what is the reason behind it?

2967


If UG power cable both ends are to be earthed or what? If not why?

1880


why Lightening Arrester Probe sharp at Top of telecom tower.

1501


Pls Breifly explain about UPS (Inverter,Reserve,Rectifier,Float voltage,Boost voltage).

2726


Why hydropower stations are preferred solution for meeting peak loads in grids?

948


What are the internal and external faults?

1048


TYPE'S OF BREKAR ,WHAT IS TRANSFORMAR & SAFTY. STARTER DOL & STAR DELTA STARTER.

2535


what is a speed of rotor when we give supply to stator of 50hz and as well as rotor of 60hz of an induction motor?????

1597


Explain difference between stand by earth fault and residual earth fault protection?

1940


A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE

2519


HOW TO CALCULATE THE HEAT AND LOAD OF LT-SUBSTATION WHICH CONTAINS 2*1MVA TRANSFORMERS,LT-SWITCH BOARD,MLDB,ACB,BUSBAR,ETC,......?

2056