Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Based on what the rating of machines are provided??(ANswer should in single word)

Answer Posted / srikant

losses....eg transformer rated in KVA because its iron
&copper losses depend upon voltage and current.losses lead
to heating which limits applied current and voltage.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is electrical diversity factor in electrical installations?

1221


What is the tension required for the 25000 CFM AHU belt

2492


how to carried out DAR test in 11 KV Alternator ?

2310


why ahould you show client/engineer activities clearly on the project plan

2787


how can we select the type of wire.what factors we have to look on it , do we have some formula to calculate it. please guide me on it

1951


Which is the oldest hydropower plant in india?

1156


what are the differant std sizes of cable trenches?

2070


What is the control action?

1158


What is the function of a neutral reactor.

1877


what is the meaning of the symbol << >> put in transformer drawing

1990


Trafo ratio is 11kV/6.6kv,Vector group is YND11. What will be the effect if secondary is used for earthed system.

3803


Can anyone tell me some hints about what type of questions are asked by the interviewer by an Electronics engineer when company is installing an IPP and wants a team of engineers?

2206


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2240




2441


Draw the vector diagram and condition for the following: 1) Dyn1 2) Ynd0 3) YnYn0

3675