The word "strain" means "extraction/contraction".
For "strain gauge" we have a fine layer of strain material which is proposed to the pressure by "diaphragm" or "fill fluid media", then it contracts/extracts according to pressure variation.
By contraction/extraction the resistance of the strain piece changes as R=(SPECIFIC DENSITY*LENGTH)/AREA, So this R varioation is taken through whetistone brigde and voltage /ampere variation.
For the strain piece all changes are in microscopic scales.
Example of the strain material is "silicon".
Ahmed Sabry
I&C Senior Engineer
Cell:+2 (0122) 1367310
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
why we use cascade control and feed forward control in 3 element drum level control measurement of steam drum .what is cascade and feed forward control system ?give example .
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
give me the formula for analog to digital converter and also d to a converter
what is compensation? temprature & pressure
what is the difference between magnetic flow meter and mass flowmeter
what is the procedure of belt scale calibration?
explain key exchanges in all security modes WPA,WPA2,TLS?
Hi my friends Is any one who can assist me in knowing the typical interview questions for system engineer at General Electric pty Ltd
Explain why use mmwc unit?
pls provide me syllabus and old question paper of instrumentation engineering for GET(JSPL)
Can anybody please let me know Orifice plate sizing calculation formula and step by step procedure
how radio frequency level probes works with its controller ? what is its principle ? pls give me brief explanation?
we are having yokogawa centum cs3000 dcs in our power plant. i need some of the operator guides NOT to appear in HIS0163 AND HIS 0162 but it shoul appear in HIS0164 HOW TO DO IT?
What is first echo & echo window in radar type level transmitter?
a flow transmitter [range-0-400mbar] connected in process line. please explain me how to calibrate the flow transmitter , & how to do static error