Answer Posted / er. avijit dixit
NGR means neutral grounding resistors....it is just used for
the purpose of solidly grounding arrangement of star
connected 3.3 kv to more stator winding of alternator. NGR
IS USED WITH A HIGH RESISTANCE FOR ABOUT 65.5 OHMS IN FOUR
PARTS MEANS 63.5*4 IS THE TOTAL VALUE. IT LIMITS THE NEUTRAL
CURRENT UP TO THE SPECIFIED CT RATIO AND ALSO PROVIDES A
DIFFERENTIAL PROTECTION TO THE STATOR WINDINGS OF
ALTERNATOR. NGR IS ALSO USED TO PREVENTS THE EARTH LEAKAGE
STRAY CAPACITANCE AND STOPS THE REVERSE SURGES. IT PROVIDES
PROTECTION TO THE PROTECTIVE CTS AND PTS AGAINST HEAVY
EARTH CURRENT FLOW DURING STABILITY LOOSE.
| Is This Answer Correct ? | 2 Yes | 2 No |
Post New Answer View All Answers
What is the earth treantment procedure?
what is active power & reactive power?
I had applied for JE in PSEB, Can you pls send me the Question bank for related to my field
how is capacitor bank look like
Why insulation level follows this order? transformer < bus bar < circuit breaker & Isolator < transmission line.
Dear Sir/Madam, I have one questions we have three steam turbines and one Gas turbine and our industry linked with the public network, we have protection system one of the protection is reverse power we can export just four MW only i would like to ask about how to calculate the reverse power. Thank you in advance best regards
-What should be minimum value of insulation resistance and maximum value of earth resistance at any electrical instillation and what is method of testing the same.
what is The difference between national electrical code and I.S.Code (electrical) and what is the value of NEC in electrical engineering field
why transformer tank is in rectangular shape what happen when it is in step shape
how hydrogen cooled alternator undergo maintanence ? that is hydrogen when come in contact with air can result into explosions .
what are inductive and capacitive voltage transformers.what are their applications
How will change the frequency in distribution side?
could anybody able 2 send me jindal steels previous papers fr electrical steam....pls send 2 my id if possible....sirisha.shaik@gmail.com
sir pls tell me . our ct specifications are 120/5 ,2 core , 0.2 and 5p10 class , 30va and 30va buden. insted of 30 va i want use 15 va. can i use?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?