Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to derive kg/cm2 to mmwc? complete derivation.

Answer Posted / kaustubh

1 kg/cm2 = 988.665 mbar = 10000 mmwc

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Full form of KKS when use DCS.

3108


There are many type of control cable like pair,core,tried, What are defination each one

2098


How to check vortex flow meter is in good condition while we do not having calibration setup?

8773


Make a ladder diagram on LSL valve will close, on PSL valve will open and start the motor

2082


Hi Friends , i need one urgent help , i am preparing for M.tech entrance examination , i need some obejective questions related to instrumentation field. where can i get those ? can anyone help me pls ?

1892


KAlman filter code for two dimension?

2015


How d.p. Transmitter can be applied to close tank?

972


what are the definitions of input, output, command & signal according to instruments controlled by PLC using DCS System?

2062


installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,

2074


why use 50% lel methane gas concentration for gas detector calibration instead of 60% lel gas concentration whereas the hi alarm set at 60% lel.

2683


A valve in series with an orifice plate (DP transmitter), is aligned for constant pressure in the pipeline, if there is an error dx, How to align it in process.

1299


Give an example where you had aproblem on the job, and tell me how you solved the problem. and the finalvoutcome.

2188


what is a good line as ic engineer as maintenance ,oc, project, calibration ,validation engineer?

1914


What is the procedure of calibration of Load cell?

1865


what is surge and how is it prevented, what is the purpose of bypass valve across AS valve.

1932