why transformer has more efficiency compare to rotating
machine?
Answer Posted / ramesh behera
The transformer which is working by mutual induction process
for which the magnetic lines of forces are linked with other
in terms of voltage and current
1- there is no relative air gap motion between two winding
such as bearing or bushes
2-the primary which act as stator but no rotating torque for
rotor only flux transmission
so as no energy loss which last for more efficiency
| Is This Answer Correct ? | 5 Yes | 1 No |
Post New Answer View All Answers
Explain the operation of grid connected central solar inverter ?
why does rotor rotets?
During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.
HOW TO SET THE EARTH FAULT SETTINGS IN ACB????????????
WHAT IS THE TOTAL POWER GENERATION IN CHHATTISGARH?
How to size Air Circuit breaker (ACB)? What is the most important factors?
hi friends ,iam working as genset AVR service engineer in electrical field from past 2 yrs throughout india . i plan to shift in some other job without travelling in same field because i con't travel,i dont know what i do for that so please guide me what job is suited for me,how i can serch the job please anybody helpme iam totally confused
what happen if field of dc shunt motor opens? what is function of putting res. in parallel to one phase of 3 phase IM? the power supplied by 5A source in circuit is given by------Watt.
how is positive, negative, zero sequence is happen.. how is effect on 3 phase system
How to setting the volume of RTCC panel AVR (11kv) controller
What's the difference between non break power supply and non break non short break power supply
Advantages of using generator circuit breaker (GCB) scheme in a power station ?
What do you mean by transformation ratio of instrument transformer?
When we have earthing mesh or underground earthing network in industrial plants, weather we have NT-S or NT-C-S kind of earthing system, so eventually weather we must use 4 or 5 wire in 400 volt level (For example 3×150+70 mm2 or 5×150 mm2) in this connection I would like to know exactly the paragraph of IEC or IEEE number
State the formula for overall efficiency of thermal power station