Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between neutral and earth?

Answer Posted / dinesh gocher

Potentioal of earth is not exect Zero every time , but
eart's potentioal always will be zero .

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2209


can i connect the two phases of scott connected transformer,if not why?

1956


How to check 11000/1.732 to 110/1.732 Potentila transformer (PT)?

2190


why does a dc machine has high efficiency while working as a generator than as a motor ..

1980


Why need 3phase machine double earthing?

1758


How dia computation perfomed in cold rolling mills .

3039


What will be the voltage impact on secondary side of two transformers with different vector groups when both voltages are compared.

1981


i have interview in Pepsi company what type of question will ask please send the question and answeer

3433


How to design the earth grid for lightning protection in an industry

4628


what is fault level of power system ?

6334


What is the operating principle of turbo-generator.

2319


How calculated single phase induction motor req. Capacitor?

1561


ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?

2009


What is the difference between AC and DC injection methods for rotor earth fault protection

2206


draw 3 phase rectifier diagram

2185