What is the difference between Earth Fault protection &
Neutral Protection
Answer Posted / a.p.nanjappa
as you are aware, in electrical engineering power
transformers or motor winding are connected in star-
undrounded or grounded,Delta connected.
Earth fault protection may be due to capacitaive
circulating current,flowing through the body of equipment
to ground. In large generator,motor it may be 5-10A
unbalanced current flowing through Neutral to ground, and
also fault current sigle phase to ground,double phase to
ground,or three phase to ground.these are severe
faluts.damages equipment severly.
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
for a 400kv t/m line with 10 ampere current will corona occur?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.
Difference between rating factor of cable and derating factor of cable?
please send the last 5 years {{{JUNIOR ENGINEER - ELECTICAL, ELECTRONICS RRB CHENNAI and secundrabad}}} TECHNICAL question papers TO MY EMAIL ID dinesh100701@gmail.com
What information we need to prepare relay coordination chart
Why the field rheostat is adjusted such that the voltmeter reads 380V
Why 1/3 is used in symmetrical components?
why to use freewheeling diode ( diode in revers bias mode) across dc coil
what is the total power generation in india?
Dear sir, In our plant have Station Transformer having capacity,i want to know, why LV side 40 - 40MVA is given? & how we can get 6.3 KV supply from tertiary(i.e. Open delta connection), Vector Group YNyn0 - yn0 +d MVA Rating 80MVA / 40 - 40MVA + 26.7MVA Voltage rating 420 (Tap range +6,to -10)81.25% /11.5KV - 11.5KV +6.3KV
Explain how to determine capacitor tolerance codes?
Why different Pressure switch used in marine boiler water circulation system
what is the difference between the voltage of 5 volts capacitor and and 5volts battery?
What is power factor why we should maintain the power factor unless what will happen