how to calculate current in HT side when we having LT
current
Answer Posted / nishil
if we know the turn ratio then we can calculate current by
using formula N1/N2=I2/I1, 1 stands for HT side and 2
stands for LT side.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
Is there any problem about which the drive (inverter) doesn't show/display the alarm and/or fault but instead of this , it doesn't work ? I want to know that could there be any kind of problem in the drive when the drive doesn't display the alarm and/or fault ?
At what speed 1 HP motor can run an electric car of weighing 400 kg?
what is the difference between fault current ant short circuit current?
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
can anyone show me how the 3 phase power is supplied to socket outlets?
Why in power plant projects we see DOL starting method used for motors upto 160 kW instead of star delta method
How to Make relay co ordination chart for a Electrical power distribution of a plant
what is the requirement regarding earthing of Single conductor with AWA
is the value of inductance depends upon the evalue of thitha in doubly excited machine?
what is the most permissible winding temp when we conducting a generator load test?(condition no load)
different aspects of voltage stability
1600kva capacity Transformers how the bucholz relay,Oil temperature,winding,surge relay relays setting are to be done
Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above
design a LV scheme for a 15 storied building?
What is meant by derating factor?