Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is meant by Active and reactive power?

Answer Posted / teja

active power: the actual power delivered to the load .
root over 3 v(line)*i(line)*cos (phi).
reactive pwer: the power which is not useful to the
load...it is the power used to compensate the losses that
occured in the machine...

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

during installation time of transformer and alternator which points we have to observed?

1942


Why is remote backup preferred to local backup?

2068


Can I use distributon class/transmission class Lightning arresots for protecting the building? If not why please explain?

1950


A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram

2816


how to compute kvar in substation feeder to improve power factor and sending voltage

2138


why swityard is necessrry requirement in any bis power distributin systems?

2374


What is the difference between isolators and electrical circuit breakers?

1184


what is Insulation monitoring device. where it is used? (in switchgear room or control panel or in field equipment)

2158


what happens in the short circuited secondary transformer,if the resistance of the short circuit is increased gradually?

2365


why not starting switch first connect in direct on line starter?????

1934


a simple c++ program to calculate simple interst with its data members as private

1868


Why the power generated in dams is complex power? Why the generators in dams cannot produce Real power directly (i.e power which has zero reactive part)?

1780


HOW TO REDUCE POWER PLANT AUXILIARY POWER CONSUMPTION?

3414


What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.

2040


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1932