Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between a PLC (Programmable logic
controller) and DCS (distributed control system)?

Answer Posted / arjunsinh k rathod

Generally PLC are used if your used I/Os are limited, like
steel and paper industries where no. of DI,DO, AI and AO
are limited on the otherhand in petrochemical processess
where I/Os are used in thousands of numbers then DCS is
useful.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

There are many type of control cable like pair,core,tried, What are defination each one

2090


can you send remote seal interface level transmitter calculation steps for oil water saperator.

2557


Basically iam Instruemntation Engineer, but Iam interested in Instruments design engineering, so plz guide, is there any course, training or Softwres to become Instrument design engineer??.

1993


Tell me the field calibration procedure step by step with diagram of pressure gauge, pressure switch, pressure transmitter, temperature switch, level switch, flow switch, flow transmitter.

3140


Explain pH, Conductivity.

2073


In which principles tx ,pressure gauge,Temp gauge,control valve works?

1764


what is the procedure to callibrate temp controller ,pressure controller,etc. suppose a temp controller showing error 1.5 degree centigrate how can i minimize it.

2296


How to fix back the valve actuator stem

1988


What is the difference between working pressure and calibration pressure of a control valve

2988


We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

1611


Explain signal isolator

1092


What is the meaning of wet leg

1174


How we can check the 2 wire proxy switch? & how it is connected to DI MODULE OF PLC?

2544


key phaser where is use and work

1902


typical loop drawing of a simple feedback control comprising of one transmitter and one control

1940