Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Which type of Oil is used in transformers, & what is its strength?

Answer Posted / shridhar awasthi

The oil is used is mineral oil,synthetic oil(Chlorinated diphenyl/askarel) and silicon oil.The synthetic oil is used to reduse the risk of fire.it is heavier than water,non-oxidising and has higher dielectric strength than mineral oil.the synthetic oil contains PCB (polychlorinated benzyne)which is hazardous for human being and handling of this oil require great precaution,which is why this oil is banned in many countries.
Silicon oil offers nearly all the advantage of synthetic oil and does not contain PCB also but ten times cost than mineral oil.
Silicon oil is an option where the fire is also a criterion.

Mineral oil in good condition appears clear and transparent.
It degrades faster due to oxidation,so anti oxidant called inhibitors are mixed with the oil to prolong it's life.
Dielectric strength of treated oil should be 50KV

Is This Answer Correct ?    3 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the physical connection of a analog i/p to a analog i/p module (ab plc)and through a analog o/p module(ab plc) to a analog o/p . and how all the process control by scada

1872


Draw the equivalent circuit of crystal oscillator?

1268


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

1404


1.dg on load alarm/stop alarm... 2.dg on load. piu alarm alarm kaise chek krte hai

1888


What is the effect of interchanging core(made of steel) and winding(made of copper) material in case of transformer? Give proper explanation in regard to different losses in transformer.

1832


what is meant by motor startup supervision & motor load jam protection ?

5936


how to calculate the battery AH

2712


what is earth resistance? how to measured? and give values at power station and mcc area?

1922


why and how voltage sharing in transformer, during magnetic balance test ?

2279


i want use the cable size 16cx4 core aluminium usege watts 240x2000w this cable size is correct?

2147


draw singleline diagram of star to delta and dol starters

2193


How npn and pnp transistor works

1079


write encoder 17 pins details? pin a;b+, pin b;w+,..pin s & t. what is the meaning of b+, w+? explain;

2103


What is referred to the electron in the outer orbit?

1096


Dear all: Recently we got a question about Interface between PMS and SAP-PM.once we got a update message from PMS.we should set the deletional flag for functional location in SAP system.Is there any FM or BAPI to use?There are only functional location create and change provided by SAP. Best regards!

2024