Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

different between circuit breaker & switchgear & relays

Answer Posted / navneet singh

circuit breaker works arc phenomenon.but relay work electomagnet wire winding by me.....

Is This Answer Correct ?    6 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT KIND OF LIGHTENING PROTECTION SCHEMS CAN BE ADOPTED FOR THE FLAT ROOF OF BIG DIMENSION.

2105


Mention the disadvantages of low power factor? How can it be improved?

1129


Why can't we parallel the secondary circuits of two voltage transformers?

1474


why HT armoured cable does not glanding

4209


Why is remote backup preferred to local backup?

2050


What is the type of feedback used in an op- amp schmitt trigger?

1011


WTA used cb?

1903


What is the permissible maximum flux density in transformer core?

1216


1600 KVA ka transformer hi aghar lt side par 800A aur voltage 420 ho to HT side ki cable ki rating keya ho gi?

2016


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2136


what is the difference betweem star connected motor & delta connected motor?

2341


What is the purpose of stablization resistor in high impedance bus bar protection

1987


What is a dc motor?

1143


How does the slip regulator works as a startor

1947


What is non-minimum phase transfer function?

1287