A motor is taking 15 Amps at no load and 60 Amps at full load.
and a valve has to open 10% at full load and 80% at no load.
How to draw ladder logic.(PLC).
Answer Posted / rahul nayak
U dont need any plc logic for such application since u can
do this project with the help of simple transducer which
will gives the mA o/p with respect to ur Amps. & just i/p
converter which will help u to open ur positioner valve.
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
Describe the function of Accumulator into the Pump
any body please send me the old question papers of ongc test.
how many type of plug are used in pneumatic control valve,name them.
what different types of problems do occur while doing instrumentation commisioning and how to solve them? please explain in detail
Why boiler chimney area oxyden sensor fixing?
how many type conductivity sensor ?
What is the calibration procedure of Drum level transmitter if range is 0 to -400 mmh2o in lab?
What is the diffrence between ff tx and non ff tx
How can test or measure the probe and extension cable to identify if the problem at the probe or cable or at the driver it self? (pleast notify the measuring method)
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
How the warning lamp of a charging-system is activated ?
I want to know about DDCMIS in detail ? please explain it. Also give name of reference books in which it is explained in detail in very simple manner.
Tr. Wiring for calibration.
What is defferent betwen ESP &PCP PUMP .HOW IT IS WORK?
what is the procedure for auto tune in masoneialn 12300 series displacer type transmitter?