Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

tell me the operation of ELCB. How it detects a fault?

Answer Posted / rupali

EARTH LEAKAGE CIRCUIT BREAKER WORKS IF IT GETS ANY CURRENTS
ACROSS EARTHING & IT DETECTS CURRENT THROUGH THIS OPERATION:
WE KNOW THE VECTOR SUM OF THREE PHASES IS EQUAL TO NEUTRAL &
EQUALS TO ZERO.IF EARTH DETECTS ANY CURRENTS THEN THROUGH
NEUTRAL FLOWS SOME AMOUNT OF CURRENT AND THE ELCB TRIPS OUT.

Is This Answer Correct ?    8 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain Energy and Power signals?

1779


Explain what are inter-poles and why they are required in a dc machine.

1098


State the points to be considered for selecting a particular type wiring.

2077


How does "OUT OF STEP" relay ,for Synchronous motor protection, work?

4350


what is power factor ? how we can calculate the low power factor and amount of capacitor for improve that low factor ?

1627


What is mean by STUB protection?

2071


What is lifting power for 1 wb/m2 and 1 A magnet?

2230


What is nichols chart?

1338


what is apparent poewr, reactive power, & active power?

2349


I have a relay contact rated at 220v dc which is supplied with a 24vdc from the panel,for it to trip the dampers(24vdc).What if the application of the relay changes so that it should work at its rated 220vdc then will it work at 24vdc supply given or any other consideration needs to be taken .....

2099


what is the safety points of vaccum circuit breaker.

2094


What do you mean by distribution transformers?

1168


A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE

2587


what is the calculation involved to design the heater to heat 10KL of water in temperature control unit?

1939


how we can come to know that motor winding resistance which showing by DMM is right or wrong???is there any chart or something that we will compare & check???

1919