Answer Posted / karthik ccel
The PS class is protection class CT. This PS class C.T is
mostly used for the differential protection for
transformers,motors etc...
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
Could the power factor on electrical system can affect the registration of the kwhr meter or the CT/PT?
What is meant by RVT and NDR ? expansion and details of it
Why sometime AVR and sometime Booster coil is used in Alternator? what is the diferance between AVR & Booster coil due to which they are selected
What would cause a 240v choke that should give 110v out on a 16w lamp to gradually increase to 160v?
Why different Pressure switch used in marine boiler water circulation system
How to calculate the fuel consumption for 600kva DG genset which connecting with 25%load?
If oil and air can withstand a high MeV when used as an insulator in a transformer, what are the values of how high for each material?
how could we calculate the no of outgoings from a 800 watt distribution board
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
Is it required to lay GI wires along with GI/MS conduits from one point to another point though separate earthing cable is conncted from DB to Socket?
How to test IR testing & magnetic balance test
plz send me Bhel, Mahagenco, sbi previous exam paper for electrical engineer on my email-id kambali_smita@yahoo.co.in
What is systematic error?
Is there any question in the name of Static Switch in UPS??
What is an ac motor?