Which wiring connection is preferred in motor for industrial
use?

Answer Posted / asif qureshi

in case of delta connection is preferred...and for the motors above 10 hp star delta time connection is advised if vfd is not available.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How the warning lamp of a charging-system is activated ?

2157


How will you calibrate an Absolute Pr.Transmitter of range 400mmHg absolute ?

1594


Any one can help me to identified, how can we interchange the device in FF

2316


how to calculate signal cable sizing? and multipair cable sizing??explain in brief?

1895


What is 3 selection available when configure the burnout protection for controller

2062






What is difference between ESD and PLC please Explain me clearly.

4373


How to convert mmWc(mili meter water colam) to tph(ton per hour)?

484


I WANT SECURITY PAPER MILL, HOSHANGABAD TEST PAPER.KINDLY SEND TO MY MAIL ID

2290


How to decrease opening & closing time of on/off valve?

967


A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

1682


How can measure flow in oil line?which type of transmitter is generally used?

3536


defination of radial vibration?

1667


Why even multiple power supplu r used in instrumentation system?

4155


hello friends, can you please send me the model paper or question paper to be prepared for hpcl examinations????????? You can mail me at rahim_here@yahoo.com waiting for your reply........... help me .. plz.....

2142


What is ultrasonic flowmeter?

631