11 KV Power cable end earth connection insulation got
burned wht is the reson pl give the resons
Answer Posted / sanjay malik
1 Generally this earth is tied with the body of that panel
in
which it is connected and there may be a leakage current in
the insulation or earth wire which cause the wire burnt.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is the maximum number of swithes that can be connected in series up to down stream point in an LV Distribution system?
What is the purpose of stablization resistor in high impedance bus bar protection
how to interlock 3 incomer-ACB,1 buscoupler ACB,... pls answer this question and if possible send me the ckt diagram..haifriends2910@gmail.com
Explain the operation carried out in thermal power stations?
What do you understand by avr?
I am shobana from Chennai. I am having my personal interview on 19th Dec at Chennai.kindly mail me the questions to mail id shobana.shanthi@gmail.com
What is the mechanism of WTI
During regenerative breaking= A rotating magnetic field is reversed B slip is positive C torque is positive D slip is negative
what is cascade speed control device?and how this device control the speed of motors?
In electrical what is earth(ground)connection, wht is the importance of it, why it is recomended to maitain below 3VAC between Neutral and earthspecially in PLC used machines?
what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero
What are the main parts of central chiller plant? Explain the function of each stage.
Is electro plating what type of load whether resistive, inductive or capacitive loads
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
what is (+) and (-) in generator field detector stand for?