Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is V0/V rating of cable

Answer Posted / wareagle

HB: slow burning on a horizontal specimen; burning rate <
76 mm/min for thickness < 3 mm.
V2 burning stops within 30 seconds on a vertical specimen;
drips of flaming particles are allowed.
V1: burning stops within 30 seconds on a vertical
specimen; drips of particles allowed as long as they are
not inflamed.
V0: burning stops within 10 seconds on a vertical
specimen; drips of particles allowed as long as they are
not inflamed.
5VB: burning stops within 60 seconds on a vertical
specimen; no drips allowed; plaque specimens may develop a
hole.
5VA: burning stops within 60 seconds on a vertical
specimen; no drips allowed; plaque specimens may not
develop

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

While performing stability test of differintial cts how to know the voltage and current on both side of the transformer?

3529


if we apply 1000ADC instead of 100ADC or We apply 50ADC instead of 100ADC,What will be happened in the test result value.Pl explain

1286


how can we make cable shedule for controll wiring ? which details must be required for it.?

2118


how to differentiate a mpcb,mcb with a contactor? Explain their working operation

2187


Why does the Solid state Rectifiers for 3-ph brake motors sometimes have 2 & sometimes 3 output terminals?

2084


1) why a dg set shows variation of power factor and load when synchronised with other dgs? 2)Why the load sharing is not become equal in all dgs?. 3)When a dg set will not run on auto start?

1986


define digital electronic

1975


how hydrogen cooled alternator undergo maintanence ? that is hydrogen when come in contact with air can result into explosions .

1907


What is the working principle of servo motor? And explain it.

1910


State thevenintheorem?

1047


WHAT DO YOU MEAN THE DIFFERENT TYPE OF CURVES OF RELAY LIKE STANDARD INVERSE, VARY INVERSE, NORMAL INVERSE, LONG INVERSE ETC....

1954


What is the unit of charge and current?

1140


What is the formula to calculate distribution transformer De-rating on iron losses basis

1829


please send privious years question papers of jindal steel and power ltd.My e mail id is rajanikant.sngh@gmail.com

2084


how u measure/calculate renge of capacitor,capacitor has no any rating tag.what is the theory of measure of capacitons.

1970