What is NAMUR standard and why its allways reletad with
Sollenoid
Answer Posted / saf
NAMUR was founded at Leverkusen on November 3, 1949, as the
body to represent the interests of the users of measurement
and control technology in the chemical industry by such
renowned experts in the field as Dr. Sturm (Bayer), Dr.
Hengstenberg (BASF) and Dr. Winkler (Hüls).
At the second meeting in December 1949, the founding
members of the working group settled the name:
Standardization association for measurement and control in
chemical industries - abbreviated to NAMUR.
In accordance with the state of the art, NAMUR’s subtitle
was changed in 1996 to "Interessengemeinschaft
Prozessleittechnik der chemischen und pharmazeutischen
Industrie" (Process Control Systems Interest Group of the
Chemical and Pharmaceutical Industries); and on 9 November
2005, the subtitle was changed again
to "Interessengemeinschaft Automatisierungstechnik der
Prozessindustrie" (Automation Systems Interest Group of the
Process Industry). The NAMUR logo remained unchanged.
In the post-war years, the main activities in process
measurement were the improvement of measurement, control
loop analysis, standardization, especially of interfaces (4-
20 mA signal, NAMUR Initiator [proximity switch]), i.e. the
emphasis was on the standardization and exchange of
experience relating to measurement and control devices.
Is This Answer Correct ? | 17 Yes | 2 No |
Post New Answer View All Answers
why any measurement made interms of pressure is more accurate ? to be more precise most of the flow velocity is made interms of pressure and it is accurate. what is the reason behind pressure measurement being accurate ?
when placing a vent or drain hole on an orifice plate should you measure from the center of the bore up or down for the vent placement?
what is the difference between scaler and vector drive
Explain about the leakage class of the control valves
protection relay watchdog contact operation?
how do i tune dearator pr control valve using PID. we set the set point is 0.6kg/cm2 now i want 0.5 to 0.7kg/cm2 limits so what should i give p,i,d values. then pls explain how do set pid values for control valve tuning?
I installed the smartplant instrument v8, but can not be opened, that always said: "INTools 2007 hardlock no found". So Could you help me how to do for that?
flow transmeter accuracy 0.075% of full scale & find ucertainty is 0.025 % so what is maximum limit band of uncertainty
List three types Level Switches with their working principles
What are the maximum packet size of: a) HART b) Profibus DP c)Profibus PA d) DeviceNet e) Foundation Fieldbus
What is standard procedure of manual mapping in Radar type level transmitter?
Explain the burnout feature.
on interface level transmitter model(RTG3302-EMERSON) What is threshold valve how can we select correct threshold value T1,T2,T3,T4 When interface water & hydro carbon
how do calibrate the valves.. with clear manual
How oil line flow measured?eplain about instruments used and working principle?