If a generator of generating station produces 100MW rated
output then what will be the rating of the step-up transformer
connected to it?
Answer Posted / praveen v
hey i have given the generator output i.e 100MW k. so now tell me the rating
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
How to measure the earth resistance value in a concrete pavement(flood light area)?
Why current shoots up in the secondary on the knee point voltage during saturation test of CT? How core saturation effects the secondary current (while the primary side is open)? What the logic behind this?
battery capacity use of made?
I completed iti in2004 I was worked in A grade contractor can I get c licence
HOW TO CALCULATE ELECTRICAL, MECHANICAL,& OVERALL EFICIENCY OF GAS ENGINE POWER PLANT
hi frnz,can somebody give me any project work? i am a 2nd year student & interested in practical works...plz give me some projects
I need bhel electrical test pattern & paper
132/6.6ππ πππππππππππ πππππππ πππ πππ πππππ πππ πππππππππ. πΈ'ππ πππππππ πππππππππππ ππ 6.6ππ/415π πππ πΈ πππππππ πππππππ ππ ππππ πππππ πππ ππ ππ 13/6.ππ πππππππππππ?? πΈπ π½π.. ππππ π ππ’??
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp β is the cross sectional area of bus bar in millimeters. I - Β Β is the value of AC fault current. t - Β Β is the operating time of disconnecting device in seconds. K β Β is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of βkβ for copper is 143.
In aerodynamic turbines which element is NOT there a.stator b.compressor c. Fuel intake system d.fans
PLZ EXPLAIN CORONA,SKIN,BIRD PALE,SPAN,SAG Effects of power cable.
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 β¦/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0ο°for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoffβs Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoffβs Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
explain different types of d.c motors?
How to convert 2 phase to 3 phase electricpower in induction moter?
DRAW ACIRCUIT DIAGRAM OF 100 KVA 415V/55-0-55V DELTA TO STAR TRANSFORMER