Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference SCR & TRIAC?

Answer Posted / raj kumar

SCR is a Silicon Control Rectifier which contorl dc output
voltage of self this is Main Member OF Transistor
Family.SCR use in AC TO DC Conversion.

Anitpararel Connection of SCR know as TRIAC it use in AC
Power system for controlling.

Is This Answer Correct ?    18 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

define the non synchoronism of synchoronous machine in general g or m??

1852


what happen if the load connected to the induction motor is taken away? the same question for synchoronous generator in synch i think that the the exitation voltage will appear on the terminal only if so plz answer me

1988


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2701


Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example?

2199


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1978


What is primary and backup protection?

1145


what are the precuation should be taken ahen installing power transformer,circuit breaker,current & potential transformer

2092


Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir

1915


i wasted one year for the job after completed my btech what can i say about 1year time in interview

2099


what is the preventive maintence for ht panels and busbars and vcb abd acb's.

2347


what is effect of 5amp fuse on 2mva pry protection of transformer

1844


I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.

2258


what exactly commisioning work does in electrical site work... LT side?..

1919


What is meant by Load Encroachment in OHL Feeder Protection?

3615


any earth foult trip the relay but in welding time not trip by earth foult

3157