Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to design power source say 5KW i/p :415v 3 ph, o/p 5KW
constant, variable currnt and variable volatge 10-230v,

Answer Posted / megh

in the case, you want
variable I and v. . Then
you require rectifier
and convertor ckt like
ups,drive. . . .by little
modification you can
vary both. . . . .

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

i want to know d working mechanism of tafe tractors next i like to know d engine type of apache bighs can anyone help me

2176


Write masons gain formula.

1147


why do we not use equivalent voltage source in negative sequence equivalent ckt.

1995


detailed procedure how we calculate cost for pcc m10 and rcc m20 including centering and labour excluding steel/ iron

3061


what is (+) and (-) in generator field detector stand for?

1782


What is effect of harmonic current (Draw by VFD) on power system/ electrical Equipments ?

2009


what is difference between line differential and transformer differential?

1684


sir, what is the importance of Fault MVA. how to calculate fault mva of 33kv substation connected by 6.5 km line(single circuit with equal spacing) with 110/11kv transformer in 110kv susbstation.the fault mva on 11 kv bus in 110kv susbstation is 208mva.

2883


quantizer means?

1881


How we can calculate the life of Lead acid battery

1717


how to calculate maximum current

2271


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1949


What is the difference IN MCCB's between thermal magnetic and electronic tripping system ?

1984


why moisture formation found in XLPE Armoured cable outer sheath

1754


why do we use 25kv supply for traction purpose?

1854