with the help of suitable diagrams different types of control
valves
Answer Posted / omak
Double acting
Single acting
Fail to Open
Fail to Close
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
applications of plc in printing and packaging?
how many type of plug are used in pneumatic control valve,name them.
I need to know steps to Calibration Valve Guard......
Basically iam Instruemntation Engineer, but Iam interested in Instruments design engineering, so plz guide, is there any course, training or Softwres to become Instrument design engineer??.
why we us isolation barrier in hazardous area how it works to protect the area and please clarify its current flow.
where proximity sensor installed on tank in loading arm application
Q-Explain the different load conditions that will produced different offset which may or may not be acceptable to thhe control function
What are the types of control valves available
what are procedure of sox-nox calibration
what does the ratio 800-400-300-200/1-1-1-1-1 in the specification of current transformer indicates?
is there any digitel grevity meter availaible in the market by which we can measure specific gravity of a battery?
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
What is feed factor and its Importance in cement industry? How we can solve feed factor?.
What is the difference bitween control net scaner and device net scaner
why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V