what is mean by NTPC?,why didn't electric shock in train?
Answer Posted / deepankar
Since the connections
are properly insulated.
However if it comes in
contact of line
conductors then also
noone get electric
shock Because of too
long length of rail
network its resistance
will also too high and
leads to flow a very
minor current.
| Is This Answer Correct ? | 2 Yes | 2 No |
Post New Answer View All Answers
ult of expression 'document.FrmQF.myem
How to do cable sizing calculation for 750 A Neutral Earthing resistor for 33kv. the 33kv cable going to swbd. is 630mm2 3 runs.
what is auto re-closer?
a)In a 3-phase 4-wire circuit, a circuit breaker is selected to protect the circuit whose highest fault level is 6.6 MVA. Determine the required minimum breaking capacity in kA. (Note: Covert 3-phase power in terms of kA to find answer.) b)Using the below, determine the required minimum making capacity in kA as a “peak value”. Rate breaking capacity (Icn) ka: Icn<= 1.5 Factor = 1.41 1.5
why use phase displacement in transformer.and effect of phase displacement on transformer
in dc series motor if field wdg is shorted then
We have Diesel generator of 200KW. fuel consumption is always same,even connected light load or full load. Is it right?
what percent do you derate your copper wire when you change from copper buss to copper wire
operation of diesel generator
What is the approximate value of stacking factor?
CPC cable .PVC \1C....I want to get sure that type is flexible indoor or to be install on trench. please advice .thanx :)
what is laser diodes?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
How to calculate the multiplying factor for energy meter with ct ratio given
can anyone explain the star-delta motor control wiring ,which wire go where and how they operate?