Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Compare salient pole and Hndrical rotor machines.

Answer Posted / sunil jatav

ok actually i am looking for the answer also but this is
what i have got so far,you can understand cylindrical rotor
in comparison to Salient pole machines. In cylindrical
rotor, as it rotates, the air gap between the rotor and
stator doesnt change due to its cylindrical shape, but for
salient pole machine, due to its shap, the air gap changes
as it rotates, due to those dents(laminations) and since air
gap is fixed for cylindrical rotor,the magnetic path
reluctance is independent in respect to its position to
magnetic poles


Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

UG cable sizes were specified in sqmm. But practically its not coming to mesure. What's the reason for that? And how they specify the size of the cable?

1918


how to put cable sizing and cable glands size for respective cable & Cable Lug size in a DB sectors???

2149


Percentage losses in power generation?

2971


why constant voltage transformer should be start without load? and if started then what will happen?

2023


Mention what are the types of semi-conductors?

1186


DG cranking voltage?

4739


why to use freewheeling diode ( diode in revers bias mode) across dc coil

4987


technically, what is the reason behind starting the motor star the delta connection .. and what other ways to do this rather than using " star-delta transformer"

1958


How we calculat the NGR of 3phase Generator, Our generation voltage 11KV

3299


What information we need to prepare relay coordination chart

2306


we are small scale industry in production of rice & rice bran. Pls let me know how to take contract demand for our industry.. (for information we have total 600.hp)

4359


sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance

2080


IN 1000kva transformer where the oil and winding temperature sensors is connected

2507


why ct's&pt'S out put called as burden,why compelsary short ckt the secondary of ct's while removing the burden?

2239


diameter of cable and core is doubled then the value of capacitance is

4275