What is the Difference Between MCCB & ACB & VCB
Answer Posted / v. k. vishwakarma
mccb is moulded case circuit breaker, is used in power
cicuits to provide isolation for circuit from high current,
short circuit and earth fault. but mccb only can use in low
current cases at 440volts.
acb is air circuit breaker, can also use in power circuits
to provide isolation in those same cases. but in high
current cases at 440volts with more functions.
vcb is vaccume circuit breaker. it is for high voltage
cases like 11kv, 33kv etc with more function than acb and
same reason of application.
| Is This Answer Correct ? | 0 Yes | 3 No |
Post New Answer View All Answers
we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan
How calculated single phase induction motor req. Capacitor?
while doing high voltage test on 11kv/433 distribution transformer why we only give 28 kv on hv side and 3kv on lv side for power transformers what is the value what factors it depends
wat is d diffr btw shunt coil and trip coil in VCB?
What is CVT and what is relation with wave trap?
The size and construction of bushings in a transformer depend upon?
Which is the oldest hydropower plant in india?
Difference of induction motor & servo motor ??
what is PDU in transformer?? which company manufacture??
I HAVE A INCOMING 100A MCCB TPN 25KA, CABLE LENGHT OF 80M 70MM CABLE SIZE FROM MAIN SUBBOARD TO NEW DB.BASE ON THE FAULT LEVEL SETTING OF 45KA.I WOULD LIKE TO FIND OUT 25KA ENOUGH KA. APPRECIATE IF SOMEBODY CAN ASSIST ME WITH FORMULA FOR THIS. FRM: JEFF
I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?
How could a garment factory benefit from renewable energy
plz tel me syllabus and exam date 4 jr executive engg (electrical)
Is there a possibility to use such a treshold voltage for the NMOS part of a CMOS circuit that during the switching it will start conducting only after the PMOS part will be already closed, by this eliminating the leakedge current? Please note, I'm not asking about the well bias in standby mode, but about the "antileakedge" measures during normal operation.
What is kvar?