Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the function and use of oil filled cables specify
its advantages and disadvantages

Answer Posted / jason008

oil filled cables are not like transformers as there are no
cooling towers for the oil to be circulated around
adv of oil or fluid filled cable. 1 Longer service life you
can mointor what is happening inside the cable you know if
a 3rd party has slightly hit the cable as you a low
pressure alarm goes off less dielectic losses smaller
conductor size for same ammount of current for xlpe see ppl
oil filled cable they have been used for many years
disav higher cost takes longer to join lead sheath of older
cables leak.. this has been improved by alum sheath
Xlpe adv cheaper less maintenance.
xlpe disadantages unable to see when the cable is going to
fail no pre warning water can migrate into xlpe greater
losses in xlpe you can not test the xlpe in the same manner
as oil cable satuation test which test stress cones ect its
the earlier joint where very hard to do.there are to many
variation of joints between diffrent companies

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why output is out of phase in case of common emitter?

2184


What will be in Mahagenco Trade Test Exam? I want to know the same.

3749


how we provide neutral earth on synchronising panel as per electrical standards?

2159


On Which Pressure PRV is operated.

1796


Is there any Electrical supervisor license which gives permit to work whole India rather than individual state??

1927


Why Utility Distribution System in India is mainly at 11 kV? Why not Utility go for 33 kV?

1786


how give earthing conection to household equipment?

2092


why Lightning arrestor are made by 2 seperate stack of inslutor but why cvt are in single stack of insulator.

2031


What the difference between three phase contactor (coil 110vac) & three phase SSR (control voltage 110Vac)? May I use contactor in place of SSR?

2204


What are the Formula of computing Back up Time of 500kVA UPS with 4 Battery Banks, each bank composed of 43 pcs of Batteries 12V150Ah. How to compute the Back up Time of UPS? We have also 3X500kVA UPS running in Parallel same composition as I write above.

1398


what is difference between earthingpits,earthing grid & earthing mess?

2559


How to decide whether A / B / C / D curve type MCB should be used?

2363


What is center gravity load in substation?

2477


why are the maintaine power factor and how can this control and this is how work.

2026


1600kva capacity Transformers how the bucholz relay,Oil temperature,winding,surge relay relays setting are to be done

1954