Answer Posted / neeraj sharma
1. should have a pc
2. should have a plc
3. should have network such as RS232 (Allen Bradley)
4. should have communication cable to communicate b/w plc & pc
ex. PM02 , CP3 etc
5. should have driver software
6. should have knowledge of programming (ladder logic , FBD , Structral text)
Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
i am from instrument branch i want paper patern of mahagenco . any pevious years paper regarding my branch send me please . please.....
If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
what is the field bus calble ? what are diffrences in orang colur cable and black coular calble ?
How to fix back the valve actuator stem
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
When doing a liquid seal on a differential flow transmitter , most of the time the sealing liquid will be heavier then the process fluid. For wich application will the sealing liquid be lighter than the process fluid if transmitter is mounted below the process line.
Explain the working of an enraf level gauge.
please send me the inteview questions in IOCL
What is shielding effect?
how can we tune a PID. If it is by zeiger nichols method..please explain briefly with help of an example.
I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.
Q-Explain the different load conditions that will produced different offset which may or may not be acceptable to thhe control function
Why not come out analog output in ABB EL3020 when display show correct value
what are the diff. in servo and regulatory control?
How can you add value to this Industry if offered the job?