Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Dear All, Pls let me know about ELR.... CBCT is using for
singnal purpose... How it works.. any body can explain
pls.......

Answer Posted / s.murugan kumar

CBCT is used for current leakage purpose via earth.If any
leakage current goes to any equipments (For example:Busduct)
it will be by pass that the leakage current to earth.So it
will act some relay.This is the CBCT purpose.This is not a
signal purpose this is protection purpose of any equipments.

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

We have 750KVA DG set, we want to introduce REF relay with 1250/1A,CL PS,Current transformers.The lead distance of 2.5mm copper flexible cable from CT to relay is around 5mtrs.We would like to know the knee point votage(VK) & IM calculion for CT's

1866


What is the armature mmf in a D.C machine?

1181


what are the reasons of CT circuit faulty in busbar protection scheme?

1421


What is a differential amplifier?

1168


would you please give me any idea about the BARC interview question on electrical? i have an interview on 1st july.....plz hlp me.......its urgent......

2409


what is the difference between dry and wet type of 132kV terminations. which one is durable

1947


what is conductor copnstant of ab cable

1817


State the factors, for the choice of electrical system for an aero turbine.

1117


when we design electrical schemes of 11/.415kv distribution..wen and were should we show the relays??what is the function of it?for example..we place EFR Relay CT between transformer neutral link and transformer earth.Like this what are the other type of relays we should use?why?where?Explain please..Thank you

1744


how to calculate differential current when we testing differential relay..suppose we have 1000kw generator,630amp VCB,what value we should put /inject so that relay trip the VCB? PLLZ justify ur comment

1525


what is KSR type transmission tower? What is LSR type transmission tower?

5332


what is reverse power relay brief explanation and in b/w where it is connected

1980


Difference between transition and diffusion capacitance

2923


what is model question rrb junior engineer electrical gr.II

1894


how we can calcultae the short circuit level for bus bar

2173